TM 5-2420-222-20-2
WARNING LIGHT LEADS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and
gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and
clothes and dont breathe vapors. Do not use near open flame or excessive heat.
The flashpoint is 100°F to 138°F (38° to 59°C). If you become dizzy while using
cleaning solvent, get fresh air immediately and get medical aid. If contact with
eyes is made, wash your eyes with water and get medical aid immediately.
12.
Clip (1)
a.
Clean in drycleaning solvent.
b.
Using clean, dry rags, wipe dry.
13.
Two grommets
a.
Clean in solution of detergent and
(2 and 3) water.
b.
Using clean water, rinse clean.
c.
Using clean, dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance
Instructions (page 2-137).
Replace defective parts which cannot be repaired.
14.
Lead (4)
a.
Look for cracked, burned, and worn
insulation.
b.
Look for broken wires.
c.
Look for loose and corroded terminals.
15.
Clip (1)
Look for cracks, breaks, and abnormal
bends.
16.
Two grommets
Look for cracks, tears, and hardening.
(2 and 3)
REPAIR
NOTE
For more information on how to repair wiring, go to General Maintenance
Instructions (page 2-137).
2-770
|