VOLTAGE REGULATOR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION - CONTINUED
22.
Terminal (1)
Terminal (2)
a.
Put on.
b.
Take off tag.
23.
Terminal (3)
Terminal (4)
a.
Put on.
b.
Take off tag.
24.
Insulator washer
Put on.
(5) and insulator
sleeve (6)
25.
Terminal (1),
Ac generator plate
Put on.
terminal (2),
assembly (7)
insulator sleeve
(6) and insulator
washer (5)
26.
Terminal (3) and
Insulator washer
Screw on until snug.
ac generator plate
(8) and new assembled
assembly (7)
washer nut (9)
27.
Terminal (1) and
Washer (10) and new
Screw on until snug.
ac generator plate
assembled washer
assembly (7)
nut (11)
28.
Ac generator plate
Two assembled
Using 3/8-inch, 3/8-inch drive socket
assembly (7) and
washer nuts
and ratchet handle, alternately tighten.
two terminals
(9 and 10)
(1 and 3)
NOTE
Steps 29 thru 31 do not apply if ac generator has been removed.
29.
Terminal (12)
Terminal (13)
a.
Put on.
b.
Take off tag.
30.
Terminal (12)
Insulator washer
Screw on and tighten, using two 7/16-
and terminal (13)
(14), new lock-
inch open-end wrenches.
washer (15) and
nut (16)
31.
Connector (17)
Connector (18)
a.
Plug in.
b.
Take off tag.
2-458
|