TM 5-2420-222-20-2 HORN WIRING HARNESS (SERIAL NUMBERS 235786 THRU 235999 ONLY) - CONTINUED ACTION LOCATION ITEM REMARKS REMOVAL - CONTINUED 3. Circuit breaker Nut (3) and a. Using 318-inch box wrench, unscrew terminal (1) lockwasher (4) and take out. and terminal (2) b. Get rid of lockwasher (4). 4. Circuit breaker Terminal (2) a. Tag (page 2-137). terminal (1) b. Take off. 5. Cowl (5) Horn wiring a. Note routing for proper placement harness (6) during installation. b. Take out. CLEANING NOTE For more information on how to clean parts, go to General Maintenance Instructions (page 2-VI-1). WARNING Electrical parts solvent cleaning compound (trichlorotrifluoroethane) is flammable, and   reacts   violently   with   aluminum,   titanium,   barium,   lithium,   samarium,   and sodium   potassium.      Cleaning   compound   fumes   displace   air   and   it   may   be carcinogenic.    Boiling  point  is  1140F  (460C).    Do  not  wear  jewelry.    Wear  rubber gloves  and  use  only  in  well  ventilated  area.    Avoid  contact  with  skin,  eyes,  and clothes and do not breathe vapors.  Do not use near open flame or excessive heat. If you become dizzy while using cleaning compound, get fresh air immediately and get medical aid.  If contact with eyes is made, wash your eyes with water and get medical aid immediately. 6. Horn wiring a. Using clean rags dampened with solvent harness (6) cleaning compound, wipe clean. b. Dip connectors in solvent cleaning compound. c. Using clean, dry rags, wipe dry. INSPECTION/REPLACEM ENT NOTE For   more   information   on   how   to   inspect   parts,   go   to   General   Maintenance Instructions (page 2-137). Replace defective parts which cannot be repaired. 2-734

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business