TM 5-2420-222-20-2
WARNING ALARM WIRING HARNESS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION - CONTINUED
18.
40 ampere circuit
Terminal (2)
a.
Put on.
breaker (1)
b.
Take off tag.
19.
40 ampere circuit
New lockwasher (3)
Screw on and tighten using 318-inch box
breaker terminal (1)
and nut (4)
wrench.
and terminal (2)
20.
Alarm switch with
Connector (6)
a.
Push on.
two terminals (5)
b.
Take off tag.
21.
Transmission (7)
Alarm wiring
Route over top of transmission (7) as
harness (8)
noted during removal.
22.
Fender (9) and
Alarm wiring
Push through hole between fender (9) and
fender support (10)
harness (8)
and fender support (10).
23.
Fender (9)
Alarm wiring
Push in through fender braces from front
harness (8)
until taut.
24.
Reverse warning
Terminal (12)
Put on.
alarm terminal (11)
25.
Reverse warning
New assembled
Screw on and tighten using 3/8-inch box
alarm terminal (11)
washer nut (13)
wrench.
and terminal (12)
26.
Alarm wiring
New plastic
a.
Put on same number in same places as
harness (8) and
bands (14)
noted during removal.
loader backhoe
b.
Using slip-joint pliers, pull tight.
2-730
|