TM 5-2420-222-20-2
WARNING ALARM WIRING HARNESS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
WARNING
Electrical parts solvent cleaning compound (trichlorotrifluoroethane) is flammable,
and reacts violently with aluminum, titanium, barium, lithium, samarium, and
sodium potassium. Cleaning compound fumes displace air and it may be
carcinogenic. Boiling point is 114°F (46°C). Do not wear jewelry. Wear rubber
gloves and use only in well ventilated area. Avoid contact with skin, eyes, and
clothes and do not breathe vapors. Do not use near open flame or excessive heat.
If you become dizzy while using cleaning compound, get fresh air immediately and
get medical aid. If contact with eyes is made, wash your eyes with water and get
medical aid immediately.
13.
Alarm wiring
a.
Using rag dampened with solvent clean-
harness (1)
ing compound, wipe clean.
b.
Dip connector (2) in solvent cleaning
compound.
c.
Using clean, dry rags, wipe dry.
INSPECTIONIREPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance
Instructions (page 2-137).
Replace defective parts which cannot be repaired.
14.
Alarm wiring
a.
Look for cracked, burned, and worn
harness (1)
insulation.
b.
Look for broken wires.
c.
Look for loose and corroded terminals.
REPAIR
NOTE
For more information on how to repair wiring, go to General Maintenance
Instructions (page 2-137).
INSTALLATION
15.
Loader backhoe
Alarm wiring
Put in next to right side of transmission.
harness (1)
2-728
|