TM 5-2420-222-20-2
VOLTAGE REGULATOR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
WARNING
Electrical parts solvent cleaning compound (trichlorotrifluoroethane) is flammable,
and reacts violently with aluminum, titanium, barium, lithium, samarium, and
sodium potassium. Cleaning compound fumes displace air and it may be
carcinogenic. Boiling point is 1140F (460C). Do not wear jewelry. Wear rubber
gloves and use only in well ventilated area. Avoid contact with skin, eyes, and
clothes and do not breathe vapors. Do not use near open flame or excessive heat.
If you become dizzy while using cleaning compound, get fresh air immediately and
get medical aid. If contact with eyes is made, wash your eyes with water and get
medical aid immediately.
14.
Connector (1)
a.
Dip in cleaning compound.
b.
Using clean, dry rags, wipe dry.
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and
gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and
clothes and dont breathe vapors. Do not use near open flame or excessive heat.
The flashpoint is 100°F to 1380F (380 to 59°C). If you become dizzy while using
cleaning solvent, get fresh air immediately and get medical aid. If contact with
eyes is made, wash your eyes with water and get medical aid immediately.
15.
All other metal
a.
Clean in drycleaning solvent.
parts
b.
Using clean, dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance
Instructions (page 2-137).
Replace defective parts as needed.
16.
Voltage
a.
Look for cracks and breaks.
regulator (2)
b.
Look for cracked, burned, or worn
insulation.
c.
Look for loose or corroded terminals.
2-456
|