TM 5-2420-222-20-2
BATTERY CONNECTOR CABLE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
WARNING
Electrical parts solvent cleaning compound (trichlorotrifluoroethane) is flammable,
and reacts violently with aluminum, titanium, barium, lithium, samarium, and
sodium potassium. Cleaning compound fumes displace air and it may be
carcinogenic. Boiling point is 114°F (460C). Do not wear jewelry. Wear rubber
gloves and use only in well ventilated area. Avoid contact with skin, eyes, and
clothes and do not breathe vapors. Do not use near open flame or excessive heat.
If you become dizzy while using cleaning compound, get fresh air immediately and
get medical aid. If contact with eyes is made, wash your eyes with water and get
medical aid immediately.
4.
Battery connector
a.
Using clean rags dampened with solvent
cable (1)
cleaning compound, wipe clean.
b.
Using clean, dry rags, wipe dry.
c.
Using battery terminal cleaner, clean
inside of terminal clamps (2 and 3)
until shiny.
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and
gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and
clothes and don't breathe vapors. Do not use near open flame or excessive heat.
The flashpoint is 1000F to 138°F (380 to 590C). If you become dizzy while using
cleaning solvent, get fresh air immediately and get medical aid. If contact with
eyes is made, wash your eyes with water and get medical aid immediately.
5.
All other metal
a.
Clean in drycleaning solvent.
parts
b.
Using clean, dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance
Instructions (page 2-137).
Replace defective parts as needed.
2-706
|