TM 5-2420-222-20-2
BATTERY GROUND CABLE
This task covers:
a.
Removal (page 2-688)
e.
Repair (page 2-690)
b.
Cleaning (page 2-689)
f.
Installation (page 2-690)
c.
Inspection/Replacement (page2-690)
INITIAL SETUP
Tools
Materials/Parts - Continued
Cleaner, battery terminal
Rags, wiping (item 21, Appendix C)
Handle, ratchet, 3/8-inch drive
Solvent, drycleaning (item 28, Appendix C)
Puller, battery terminal
Socket, 3/8-inch drive, 9/16-inch
Personnel Required
Wrench, box, 1/2-inch
Wrench, open-end, 1/2-inch
One
Materials/Parts
Equipment Condition
Cleaning compound, solvent (item 4,
Battery cover removed (page 2-1110)
Appendix C)
Grease (LO 5-2420-222-12)
Lockwasher, ground cable and pedal stop
screw
Paper, abrasive, fine (item 20,
Appendix C)
ACTION
LOCATION
ITEM
REMARKS
NOTE
Loader backhoes with Serial Numbers 235786 thru 235999 have battery ground cable called
battery ground cable. Loader backhoes with Serial Numbers 319995 thru 342573 have battery
ground cable called battery lead. Although length and appearance may vary, the maintenance
procedures are the same.
DISCONNECTION
WARNING
Do not smoke, use open flame, or allow sparks near batteries. The mixture of oxygen and
hydrogen gases released from batteries is highly flammable and can explode causing serious
injury or death.
2-696
|