TM 5-2420-222-20-2
BATTERIES
This task covers:
a.
Testing (page 2-692)
d.
Inspection/Replacement (page 2-694)
b.
Removal (page 2-692)
e.
Installation (page 2-694)
c.
Cleaning (page2-694)
INITIAL SETUP
Tools
Equipment Condition
Handle, ratchet, 318-inch drive
1.
Battery starter cable disconnected
Socket, deep, 3/8-inch drive,
(page 2-710)
7/16-inch 2.
Battery connector cable removed
(page 2-704)
ACTION
LOCATION
ITEM
REMARKS
TESTING
NOTE
For information on how to test batteries, go to TM 9-6140-200-14.
REMOVAL
WARNING
Do not smoke, use open flame, or allow sparks near batteries. The mixture of oxygen and
hydrogen gases released from batteries is highly flammable and can explode causing serious
injury or death.
Electrolyte and battery corrosion can cause injury. Wear safety goggles and gloves. If for any
reason electrolyte or battery corrosion contacts the eyes, skin, or clothing, flush immediately with
large amounts of cool water and seek medical attention immediately.
1.
Two hook bolts (1)
Two nuts (3)
Using 7/16-inch, 3/8-inch drive deep
and battery
and washers (4)
socket and ratchet handle, unscrew and
retainer (2)
take off.
2-692
|