TM 5-2420-222-20-2
REVERSE WARNING ALARM GROUND WIRE ASSEMBLY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-
137).
Replace defective parts as needed.
6.
Cable (1) with
a.
Look for cracked, burned, and worn
assembled terminals
insulation.
(2 and 3)
b.
Look for broken wires.
c.
Look for loose and corroded terminals.
REPAIR
NOTE
For more information on how to repair wiring, go to General Maintenance Instructions (page 2-
137).
INSTALLATION
NOTE
New wires are manufactured to required length from bulk items. For more information on
manufacturing new wires, go to Appendix D.
7.
Alarm (4)
Terminal (3) and
Put in place.
assembled cable (1)
8.
Plate (5)
Screw (7),
Screw together and tighten using 1/2-inch
left backhoe
washer (8), new
box wrench, 1/2-inch, 3/8-inch drive
control guard (6),
lockwashers (9),
socket, and ratchet handle.
alarm (4), and
and nut (10)
terminal (3)
9.
Terminal (11)
Terminal (2)
a.
Put on.
b.
Take off tag.
2-690
|