TM 5-2420-222-20-2
REVERSE WARNING ALARM SENSITIVE SWITCH AND FITTING - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSPECTION/REPLACEMENT- CONTINUED
8.
Switch (1) and
a.
Look for cracks, breaks, and abnormal
special fitting (2)
bends.
b.
Look for damaged threads.
REPAIR
9.
Switch (1)
If threads are damaged, using thread
restoring file, restore threads.
INSTALLATION
10.
Special fitting (2)
Nut (3)
Screw to top of threads.
Nut is part of fitting and does not
come off.
11.
Special fitting (2)
New packing (4)
Put on.
12.
Reverser valve
Special fitting (2)
Screw in and tighten, using 9/16-inch
housing (5)
with assembled
open-end wrench, so hole faces rear of
packing (4)
loader backhoe.
13.
Special fitting (2)
Nut (3)
Using two 9/16-inch open-end wrenches,
and packing (4)
screw down and tighten pressing packing
(4) against reverser control housing (5).
14.
Special fitting (2)
Switch (1)
Screw in and tighten using 7/8-inch 12-
point box wrench.
15.
Two terminals (6)
Connector (7)
a.
Push on.
b.
Take off tag.