TM 5-2420-222-20-2
ENGINE STARTING AID SOLENOID LEAD - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
WARNING
Drycleaning solvent PD680 is toxic and flammable. Wear protective goggles and gloves and use
only in a well ventilated area. Avoid contact with skin, eyes, and clothes and dont breathe vapors.
Do not use near open flame or excessive heat. The flashpoint is 1000F to 138°F (380 to 590C). If
you become dizzy while using cleaning solvent, get fresh air immediately and get medical aid. If
contact with eyes is made, wash your eyes with water and get medical aid immediately.
13.
All metal parts
a.
Clean in drycleaning solvent.
b.
Using clean, dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-
137).
Replace defective parts which cannot be repaired.
14.
Lead (1)
a.
Look for cracked, burned, and worn
insulation.
b.
Look for broken wires.
c.
Look for loose and corroded terminals.
15.
All metal parts
Look for cracks, breaks, and abnormal
bends.
REPAIR
NOTE
For more information on how to repair wiring, go to General Maintenance Instructions (page 2-
137).
INSTALLATION
16.
Loader backhoe
Lead (1)
Routing as noted during removal, put in
place.
2-614
|