TM 5-2420-222-20-2
LIGHT SWITCH - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
1. HD terminal (1)
Connector (2)
a.
Tag (page 2-137).
b.
Unplug.
2. FL terminal (3)
Connector (4)
a.
Tag (page 2-137).
b.
Unplug.
3. B terminal (5)
Connector (6)
a.
Tag (page 2-137).
b.
Unplug.
4. TL terminal (7)
Connector (8)
a.
Tag (page 2-137).
b.
Unplug.
5. Lever (9) and
Screw (11) and
a.
Using 3/16-inch flat-tip screwdriver,
light switch (10)
lockwasher (12)
unscrew and take out.
b.
Get rid of lockwasher (12).
6. Light switch (10)
Lever (9)
Take off.
7. Cowl (13) and
Nut (14) and
a.
Using 5/8-inch open-end wrench,
light switch (10)
lockwasher (15)
unscrew and take off.
b.
Get rid of lockwasher (15).
8. Cowl (13)
Light switch (10)
Take out.
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance
Instructions (page 2-137).
WARNING
Electrical parts solvent cleaning compound (trichlorotrifluoroethane) is flammable,
and reacts violently with aluminum, titanium, barium, lithium, samarium, and
sodium potassium. Cleaning compound fumes displace air and it may be
carcinogenic. Boiling point is 1140F (460C). Do not wear jewelry. Wear rubber
gloves and use only in well ventilated area. Avoid contact with skin, eyes, and
clothes and do not breathe vapors. Do not use near open flame or excessive heat.
If you become dizzy while using cleaning compound, get fresh air immediately and
get medical aid. If contact with eyes is made, wash your eyes with water and get
medical aid immediately.
2-590
|