TM 5-2420-222-20-2
STARTER SWITCH - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions
(page 2-137).
Replace defective parts which cannot be repaired.
8.
Starter switch (1)
Look for cracks, breaks, or abnormal
bends.
9.
Cap (2)
Look for torn or missing rubber cover.
10.
All threaded
Look for damaged threads.
parts
REPAIR
11.
Starter switch (1)
If threads are damaged, using thread
restoring file, restore threads.
INSTALLATION
12.
Starter switch (1)
Nut (3)
Screw on to position noted during removal.
13.
Control box (4)
Starter switch (1)
Put in place.
with assembled
nut (3)
CAUTION
Screw on cap by metal base to keep from tearing rubber cover.
14.
Starter switch (1)
Cap (2)
Screw on and tighten.
and control box (4)
15.
Two terminals (5)
Connector (6)
a.
Push on.
b.
Take off tag.
2-574
|