TM 5-2420-222-20-2
STARTER SWITCH - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
1.
Two terminals (1)
Connector (2)
a.
Tag (page 2-137).
b.
Pull off.
CAUTION
Unscrew cap by metal base to keep from tearing rubber cover.
2.
Starter switch (3)
Cap (5)
Unscrew and take off.
and control box (4)
3.
Control box (4)
Starter switch (3)
Take out.
with assembled
nut (6)
4.
Starter switch (3)
Nut (6)
Noting position for proper placement
during installation, unscrew and take off.
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions
(page 2-137).
WARNING
Electrical parts solvent cleaning compound (trichlorotrifluoroethane) is flammable,
and reacts violently with aluminum, titanium, barium, lithium, samarium, and sodium
potassium. Cleaning compound fumes displace air and it may be carcinogenic.
Boiling point is 114°F (460C). Do not wear jewelry. Wear rubber gloves and use only
in well ventilated area. Avoid contact with skin, eyes, and clothes and do not breathe
vapors. Do not use near open flame or excessive heat. If you become dizzy while
using cleaning compound, get fresh air immediately and get medical aid. If contact
with eyes is made, wash your eyes with water and get medical aid immediately.
5.
Starter switch (3)
a.
Using clean rag dampened with solvent
cleaning compound, wipe clean.
b.
Using clean, dry rag, wipe dry.
2-572
|