TM 5-2420-222-20-2
IGNITION LOCK SWITCH AND KEY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and
gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and
clothes and dont breathe vapors. Do not use near open flame or excessive heat.
The flashpoint is 1000F to 138°F (380 to 590C). If you become dizzy while using
cleaning solvent, get fresh air immediately and get medical aid. If contact with eyes is
made, wash your eyes with water and get medical aid immediately.
14.
All other metal
a.
Clean in drycleaning solvent.
parts, including
b.
Using clean, dry rags, wipe dry.
ignition key (1)
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions
(page 2-137).
Replace defective parts which cannot be repaired.
15.
All metal parts,
Look for cracks, breaks, and abnormal
including ignition
bends.
key (1)
16.
All threaded
Look for damaged threads.
parts
REPAIR
17.
Ignition lock
If threads are damaged, using thread
switch (2)
restoring file, restore threads.
INSTALLATION
18.
Control box (3)
Ignition lock
Put in place.
switch (2)
19.
Ignition lock
Washer (4) and
Holding switch (2) to keep it from turning,
switch (2) and
special nut (5)
screw on and tighten using 7/8-inch open-
control box (3)
end wrench.
20.
BATT terminal (6)
Terminal (7)
a.
Put on.
b.
Take off tag.
2-568
|