TM 5-2420-222-20-2
AC GENERATOR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and
gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and
clothes and dont breathe vapors. Do not use near open flame or excessive heat.
The flashpoint is 1000F to 138°F (380 to 590C). If you become dizzy while using
cleaning solvent, get fresh air immediately and get medical aid. If contact with
eyes is made, wash your eyes with water and get medical aid immediately.
15.
Ac generator (1)
a.
Using clean rag dampened in dry-
cleaning solvent, wipe outside clean.
b.
Using clean, dry rags, wipe dry.
16.
All other metal
a.
Clean in drycleaning solvent.
parts
b.
Using clean, dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions
(page 2-VI-1).
Replace defective parts as needed.
17.
Ac generator (1)
a.
Look for cracks and breaks in housing.
b.
Look for broken terminals.
c.
Turn rotor shaft.
Rotor should turn freely with some
drag from brushes, but no binding.
18.
Ac generator plate
a.
Look for cracks, breaks, and abnormal
assembly (2)
bends.
b.
Look for corroded terminal.
c.
Look for burned diode.
19.
All other metal
Look for cracks, breaks, and abnormal
parts
bends.
20.
All threaded parts
Look for damaged threads.
2-440
|