TM 5-2420-222-20-2
FUEL LEVEL GAGE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only in
a well ventilated area. Avoid contact with skin, eyes, and clothes and dont breathe vapors. Do not use
near open flame or excessive heat. The flashpoint is 100°F to 138°F (38°to 59°C). If you become dizzy
while using cleaning solvent, get fresh air immediately and get medical aid. If contact with eyes is made,
wash your eyes with water and get medical aid immediately.
11.
All other metal
a.
Clean in drycleaning solvent.
parts
b.
Using clean, dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-137).
Replace defective parts which cannot be repaired.
12.
Liquid
a.
Look for cracks, breaks, and dents.
indicator (1)
b.
Look for unreadable dial.
13.
Bracket (2)
Look for cracked and broken insulating
grommets.
14.
All metal parts
Look for cracks, breaks, and abnormal
bends.
15.
All threaded parts
Look for damaged threads.
REPAIR
16.
Liquid
If threads are damaged, using screw
indicator (1)
threading set, restore threads.
INSTALLATION
17.
Dash (3)
Liquid Put in.
indicator (1)
2-542
|