TM 5-2420-222-20-1
V-BELT ADJUSTMENT - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
NOTE
If V-belt tension is correct, skip steps 7 thru 9.
7.
Ac generator
Screw (10)
Using 1/2-inch, 3/8-inch drive socket and
adjusting strap (7),
ratchet handle, loosen.
guard (1), If
present, and
ac generator (3)
8.
Ac generator
Ac generator (3)
a. To increase V-belt tension, move farther
adjusting strap (7),
away from fan pulley (11).
engine accessory
b. To decrease V-belt tension, move closer
bracket (2), and
to fan pulley (11).
double angle
c. Hold in position while performing Step 9.
bracket (4)