![]() TM 5-2420-222-20-1 
V-BELT ADJUSTMENT - CONTINUED 
ACTION 
LOCATION 
ITEM 
REMARKS 
NOTE 
If V-belt tension is correct, skip steps 7 thru 9. 
7. 
Ac generator 
Screw (10) 
Using 1/2-inch, 3/8-inch drive socket and 
adjusting strap (7), 
ratchet handle, loosen. 
guard (1), If 
present, and 
ac generator (3) 
8. 
Ac generator 
Ac generator (3) 
a. To increase V-belt tension, move farther 
adjusting strap (7), 
away from fan pulley (11). 
engine accessory 
b. To decrease V-belt tension, move closer 
bracket (2), and 
to fan pulley (11). 
double angle 
c.  Hold in position while performing Step 9. 
bracket (4) 