![]() TM 5-2420-222-20-1 
RADIATOR - CONTINUED 
ACTION 
LOCATION 
ITEM 
REMARKS 
REMOVAL - CONTINUED 
22. 
Tie rod (1) and 
Special nut (3) 
a. Using 9/16-inch, 3/8-inch drive deep 
fuel tank (2) 
and washer (4) 
socket, 5-inch extension, and ratchet 
handle, unscrew and take out. 
b. Get rid of special nut (3). 
23. 
Fuel tank (2) 
Tie rod (1) with 
Take out. 
assembled parts 
DISASSEMBLY 
24. 
Radiator (5) 
Packing (6) 
Take off. 
25. 
Oil cooler (7) 
Four nuts (8), 
a. Using 1/2-inch open-end wrench, un- 
and radiator (5) 
lockwashers (9), 
screw and take off. 
and washers (10) 
b. Get rid of lockwashers (9). 
26. 
Radiator (5) 
Oil cooler (7) with 
Take off. 
assembled parts 
27. 
Draincock (11) 
Using 9/16-inch open-end wrench, 
unscrew and take out. 
28. 
Overflow hose (12) 
a. Pull off of radiator nipple. 
b. Take out of radiator clips. 
29. 
Tie rod (1) 
Special nut (13) 
a. Secure tie rod (1) in machinist's vise. 
and washer (14) 
b. Using 9/16-inch open-end wrench, un- 
screw and take off. 
c.  Take out of machinist's vise. 
WARNING 
Water soluble cleaning compound solvent is flammable and fumes are toxic. Flashpoint is 220F (104C). 
Boiling point is 212F (100C). Do not store in temperatures above 150F (65C) or below 35F (2C). Do 
not use near open flame or excessive heat. Do not wear Jewelry, wear rubber gloves and goggles, and 
use only in well ventilated area. Avoid contact with skin, eyes, and clothes, and don't breathe vapors. 
Avoid contact with acids, aluminium, or zinc; chemical reaction may result. If you become dizzy while 
using cleaning compound solvent, get fresh air immediately and get medical aid. If contact with eyes is 
made, wash your eyes with water and get medical aid immediately. 