![]() TM 5-2420-222-20-1 
AIR CLEANER - CONTINUED 
ACTION 
LOCATION 
ITEM 
REMARKS 
ASSEMBLY 
21. 
Air cleaner (1) 
Air cleaner 
Install (page 2-1792). 
restriction 
indicator 
NOTE 
Air cleaner filter element must seal properly against air cleaner housing so that air restriction 
indicator will work. 
22. 
Air cleaner filter 
Place In position. 
element (2) 
23. 
Air cleaner filter 
Special screw (3) 
Screw in and tighten. 
element (2) and 
air cleaner (1) 
24. 
Air cleaner (1) and 
Cover with attached 
a. Place in position. 
special screw (3) 
wingnut (4) 
b. Screw on and tighten. 
25. 
Air cleaner (1) 
Unloader valve (5) 
Place in position. 
INSTALLATION 
26. 
Fuel tank (6) 
Air cleaner (1) 
Place in position. 
27. 
Air cleaner (1) 
Spacer (7), new 
Screw in and tighten using 9/16-inch, 
and fuel tank (6) 
lockwasher (8), 
1/2-inch drive socket and ratchet handle. 
and screw (9) 
28. 
Two new lockwashers 
Screw in and tighten using 9/16-inch, 
(10) and screws (11) 
1/2-inch drive socket and ratchet handle. 