TM 5-2420-222-20-1
AIR CLEANER - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
ASSEMBLY
21.
Air cleaner (1)
Air cleaner
Install (page 2-1792).
restriction
indicator
NOTE
Air cleaner filter element must seal properly against air cleaner housing so that air restriction
indicator will work.
22.
Air cleaner filter
Place In position.
element (2)
23.
Air cleaner filter
Special screw (3)
Screw in and tighten.
element (2) and
air cleaner (1)
24.
Air cleaner (1) and
Cover with attached
a. Place in position.
special screw (3)
wingnut (4)
b. Screw on and tighten.
25.
Air cleaner (1)
Unloader valve (5)
Place in position.
INSTALLATION
26.
Fuel tank (6)
Air cleaner (1)
Place in position.
27.
Air cleaner (1)
Spacer (7), new
Screw in and tighten using 9/16-inch,
and fuel tank (6)
lockwasher (8),
1/2-inch drive socket and ratchet handle.
and screw (9)
28.
Two new lockwashers
Screw in and tighten using 9/16-inch,
(10) and screws (11)
1/2-inch drive socket and ratchet handle.
29.
Pipe (12) and
Hose (13) with
Slide down.
air cleaner (1)
assembled two
clamps (14)
30.
Hose (13)
Two clamps (14)
Using 1/4-inch flat-tip screwdriver,
tighten.