AIR INLET HOUSING - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION - CONTINUED
WARNING
Ether burns easily. If engine starting aid is not properly installed, do not release ether in
confined areas or near open flame. Engine primer fluid cylinder is pressurized to expel
ether when fluid injection solenoid is activated. Do not heat engine primer fluid cylinder
or place it in fire.
20. Elbow (1)
Tube (2) with
Place in position.
assembled nut (3)
21.
Nut (3)
Screw on and tighten using 3/8-inch open-
end wrench.
22. Air inlet (4)
Hose (6) with
Slide down.
and pipe (5)
assembled two
clamps (7)
23. Hose (6)
Two clamps (7)
a. Place in position.
b. Using 1/4-inch flat-tip screwdriver,
tighten.
TASK ENDS HERE
TA242822
2-236