TM 5-2420-222-20-1
LUBRICATING COOLER-TO-WATER PUMP COOLANT LINES - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION - CONTINUED
28.
Plate (1) and
Screw (3) and
Screw in and tighten using 9/16-inch,
fillerneck (2)
new lockwasher (4)
1/2-inch drive socket and ratchet handle.
29.
Loader backhoe
Fan blade and
Install (page 2-431).
Pulley
Do not shut down engine at this time.
30.
Engine
Run at high idle (TM 5-2420-222-10).
31.
Lubricating cooler-
a. Check for leaks.
to-water pump
b. If leaking at any connection, tighten
coolant lines
clamp using 1/4-inch flat-tip
screwdriver.
c. If leaking does not stop, shut down
engine (TM 52420-222-10) and
replace defective component as
outlined in this task.
32.
Radiator
If coolant leak was found, fill
(page 2-368).
33.
Engine
If still running, shut down
(TM 5-2420-222-10).
2-182
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |