![]() TM 5-2420-222-20-1 
LUBRICATING COOLER-TO-WATER PUMP COOLANT LINES - CONTINUED 
ACTION 
LOCATION 
ITEM 
REMARKS 
INSTALLATION - CONTINUED 
28. 
Plate (1) and 
Screw (3) and 
Screw in and tighten using 9/16-inch, 
fillerneck (2) 
new lockwasher (4) 
1/2-inch drive socket and ratchet handle. 
29. 
Loader backhoe 
Fan blade and 
Install (page 2-431). 
Pulley 
Do not shut down engine at this time. 
30. 
Engine 
Run at high idle  (TM 5-2420-222-10). 
31. 
Lubricating cooler- 
a. Check for leaks. 
to-water pump 
b. If leaking at any connection, tighten 
coolant lines 
clamp using 1/4-inch flat-tip 
screwdriver. 
c.  If leaking does not stop, shut down 
engine  (TM 52420-222-10) and 
replace defective component as 
outlined in this task. 
32. 
Radiator 
If coolant leak was found, fill 
(page 2-368). 
33. 
Engine 
If still running, shut down 
 (TM 5-2420-222-10). 