![]() TM 5-2420-222-20-1 
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED 
MALFUNCTION 
TEST OR INSPECTION 
CORRECTIVE ACTION 
7. JAW CONTROL (DIRECT LINEAR) VALVE LINKAGE STICKS OR BINDS 
Check jaw control (direct linear) valve linkage by doing the following: Using long roundnose pliers, straighten 
ends of cotter pin (6) and take out of link (7). Take link (7) out of plunger (8). Check linkage for sticking or 
binding. 
2-117 
 | 
| 
 