TM 5-2420-222-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
7. JAW CONTROL (DIRECT LINEAR) VALVE LINKAGE STICKS OR BINDS
Check jaw control (direct linear) valve linkage by doing the following: Using long roundnose pliers, straighten
ends of cotter pin (6) and take out of link (7). Take link (7) out of plunger (8). Check linkage for sticking or
binding.
2-117
|