TM 5-2420-222-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 5. Using 1/4-inch flat-tip screwdriver, loosen screw (1) and take off terminal (2). Turn ignition lock switch (3)
counterclockwise to accessory. Have assistant touch terminal (2) against front support (11) for a few
seconds. Note reading on fuel level gage (4). Turn ignition lock switch (3) clockwise to off.
2-91
|