ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Start and run engine at 1500 rpm for 15 minutes (TM 5242022210). Turn on front lights (TM
5242022210). Using thermometer and 6inch machinist's steel rule measure temperature 1inch (25.4mm)
from voltage regulator (4). Using multimeter set to 30 vdc scale, place red probe on ac generator terminal
(5) and black probe on ac generator terminal (3). Multimeter reading should be as specified in
temperature voltage chart below. Turn off front lights and shut down engine (TM 5-2420-222-10).
Temperature
Voltage
40F (4C)
14.4 - 14.9 volts
60F (16C)
14.3 - 14.7 volts
80F (27C)
14.2 - 14.6 volts
100F (38C)
14.0 - 14.4 volts
120F(49C)
13.8 - 14.3 volts
40F (60C)
13.6 - 14.1 volts
a.
If multimeter reading is correct at ac generator terminal (5), check loader backhoe for other
electrical system malfunctions.
b.
If multimeter reading Is not correct at ac generator terminal (5), replace voltage regulator
(page 2-452).