ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 3.
Using multimeter set to 30 vdc scale, place red probe on ac generator terminal (1) and black probe on
ac generator terminal (2). Check for reading of 0 vdc on multimeter.
a.
If multimeter reads 0 vdc, go to step 5.
b.
If multimeter reads more than 0 vdc, record reading and go to step 4.
Step 4.
Using multimeter set to 30 vdc scale, place red probe on ac generator terminal (3) and black probe on
ac generator terminal (1). Note reading on multimeter.
a.
If multimeter reading Is same as recorded In step 3, replace ac generator (page 2-436).
b.
If multimeter reading is not same as recorded in step 3, check loader backhoe for other
electrical system malfunctions.
TA242736