BLADE CONTROL VALVE (LIFT AND TILT) REPAIR - CONTINUED
0245 21
DISASSEMBLY - CONTINUED
CAUTION
Lever inside control lever housing is interlocked with spool in main valve body. To avoid damage to parts,
move control lever housing horizontally to remove lever from spool, then lift control lever housing off main
valve body.
27.
Remove three bolts (61), one bolt (62) and control lever housing (63) from main valve body (30).
28.
Remove O-ring (64) from bottom of control lever housing (63). Discard O-ring.
29.
Remove four bolts (65), washers (66), cover (67) and
68 67
75
gasket (68) from control lever housing (63). Discard
65
69
gasket.
76
72
70
62
30.
Remove bolt (69) from lever (70) inside control lever
housing (63).
31.
Remove shaft (4) and lever (70) from control lever
housing (63). If necessary, remove key (71) from
shaft.
71
66
63
32.
Remove bearing (72) from one side of control lever
4
housing (63) and remove preformed packing (73) and
bearing (74) from other side of housing. Discard pre-
61
64
formed packing.
73
33.
Remove adapter (75) from control lever housing (63).
74
Remove O-ring (76) from adapter. Discard O-ring.
30
421-0065
0245 21-5