TM 5-2410-237-23
ENGINE OIL PUMP REPAIR - CONTINUED
0245 08
DISASSEMBLY - CONTINUED
7
8
10
1
6
2
5
22
4
3
21
20
19
18
9
23
15
17
16
14
13
12
11
421-0074
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition. Failure to follow this
warning may cause injury or death.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. DO NOT direct compressed air against human skin. Failure to
follow this warning may result in injury. Make sure air stream is directed away from user and other
personnel in the area. To prevent injury, user must wear protective goggles or face shield.
1.
Clean all components in solvent cleaning compound.
2.
Thoroughly dry all components with pressurized air.
3.
Inspect components for nicks, burrs, cracks, breaks, distortion or other damage IAW WP 0241 00.
4.
Remove small nicks or burrs with a hone or abrasive cloth.
0245 08-3
Change 1
|