Click here to make tpub.com your Home Page

Page Title: A/C UNIT INSTALLATION - CONTINUED
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home
   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-2410-237-23
AIR CONDITIONING INSTALLATION INSTRUCTIONS - CONTINUED
0229 03
A/C UNIT INSTALLATION - CONTINUED
WARNING
Particles blown by compressed air are hazardous. Use a maximum of 30 psi (207 kPa) when cleaning com-
ponents. DO NOT direct compressed air against human skin. Failure to follow this warning may result in
injury. Make sure air stream is directed away from user and or personnel in area. To prevent injury, user
must wear protective goggles or face shield.
52.
Cut hoses to length. Clean out hose with clean, dry
compressed air before installing fittings.
38
53.
Install compressor fittings (70 and 71) on hoses (72
and 73).
54.
Place fitting (70) with large No. 12 hose in left port of
71
compressor (38), as shown.
55.
Place fitting (71) with small No. 8 hose in right port of
compressor (38), as shown.
70
73
72
421-0341-1
56.
Secure hose assemblies (72 and 73) with plate (69)
and new (3/8-24 x 2 in.) bolt (67) and washer (68).
69
68
67
73
72
421-0342
0229 03-11
Change 1

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business