TM 5-2410-237-23
AIR CONDITIONING INSTALLATION INSTRUCTIONS - CONTINUED
0229 03
A/C UNIT INSTALLATION - CONTINUED
WARNING
Particles blown by compressed air are hazardous. Use a maximum of 30 psi (207 kPa) when cleaning com-
ponents. DO NOT direct compressed air against human skin. Failure to follow this warning may result in
injury. Make sure air stream is directed away from user and or personnel in area. To prevent injury, user
must wear protective goggles or face shield.
52.
Cut hoses to length. Clean out hose with clean, dry
compressed air before installing fittings.
38
53.
Install compressor fittings (70 and 71) on hoses (72
and 73).
54.
Place fitting (70) with large No. 12 hose in left port of
71
compressor (38), as shown.
55.
Place fitting (71) with small No. 8 hose in right port of
compressor (38), as shown.
70
73
72
421-0341-1
56.
Secure hose assemblies (72 and 73) with plate (69)
and new (3/8-24 x 2 in.) bolt (67) and washer (68).
69
68
67
73
72
421-0342