HYDRAULIC FILTER SCREEN ASSEMBLY REPAIR - CONTINUED
0219 00
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic mate-
rial. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in well-venti-
lated areas. Keep away from open flames and other sources of ignition.
1.
Wash screen in clean solvent cleaning compound IAW instructions in WP 0241 00.
2.
Inspect screen assembly components IAW instructions WP 0241 00.
ASSEMBLY
1.
Install tube (6) in bottom of screen (1).
4
2.
Install valve (5), spring (3) and spacer (2) in top of
screen (1) on tube (6).
2
WARNING
3
Eye protection is required when using
press to compress spring.
3.
Use press to hold screen (1) assembly and compress
spring (3). Install ring (4).
5
4.
Install hydraulic filter assembly and filler strainer (WP
1
6
387-380
END OF WORK PACKAGE
0219 00-2