TM 5-2410-237-23
HYDRAULIC FILTER ASSEMBLY AND FILLER STRAINER REPLACEMENT - CONTINUED
0218 00
FILLER STRAINER REMOVAL
1.
Remove filler cap (11) from hydraulic tank (2).
11
2.
Remove retaining ring (12) from filler neck.
12
3.
Remove filler strainer (13) from hydraulic tank (12).
13
10
2
FILLER STRAINER CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic mate-
rial. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in well-venti-
lated areas. Keep away from open flames and other sources of ignition.
1.
Use solvent cleaning compound to clean filler strainer.
2.
Inspect filler strainer and retaining ring for damage. Replace if damaged.
FILLER STRAINER INSTALLATION
1.
Install filler strainer (13) into filler neck of hydraulic tank (2).
2.
Install retaining (12) to secure filler strainer (13) in filler neck.
3.
Check oil level in sight gage (10) on hydraulic tank (2). Add oil as needed until level is visible in sight gage. Refer to
PMCS Introduction (WP 0009 00) to determine grade of oil IAW expected temperature range of operation.
4.
Install filler cap (11) and tighten.
END OF WORK PACKAGE
0218 00-4
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |