Click here to make tpub.com your Home Page

Page Title: INSTALLATION
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home
   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-2410-237-23
HYDRAULIC SYSTEM OIL SAMPLING VALVE AND HOSE
ASSEMBLY REPLACEMENT - CONTINUED
0217 00
REMOVAL - CONTINUED
CAUTION
Do not remove adapter unless inspection shows need for replacement. Adapter may be damaged upon
removal.
5.
Remove adapter (7) and O-ring (8) from hydraulic
5
12
13,14,15
manifold. Discard O-ring.
6.
Remove reducer (5) from fitting (9).
3
7.
Remove adapter (2) from adapter (10).
8.
Remove adapter (10) from fitting (9).
9
9.
Remove nut (11) and fitting (9) from angle bracket
(12).
11
6
10.
Remove two capscrews (13), washers (14), spacers
10
3
2
(15) and angle bracket (12).
INSTALLATION
NOTE
Lightly coat new O-rings with clean oil
4
before installation.
7,8
1.
Install two spacers (15) and angle bracket (12) with
two washers (14) and capscrews (13).
2.
Install fitting (9) on angle bracket (12) and secure with
nut (11).
3.
Install adapter (10) and adapter (2).
4.
Install reducer (5) to fitting (9).
5.
If removed, install new O-ring (8) and adapter (7) in
hydraulic manifold.
387-526
6.
Install elbow (4) to adapter (7).
7.
Connect hose assembly (6) to elbow (4) and tighten hose nut. Connect other end of hose assembly to reducer (5) and
tighten hose nut.
8.
Install new O-ring (3) onto oil sampling valve (1).
9.
Install oil sampling valve (1) into adapter (2) and hand tighten valve.
10.
Run engine and check for leaks (TM 5-2410-237-10).
END OF WORK PACKAGE