HYDRAULIC PUMP LINES AND FITTINGS REPLACEMENT - CONTINUED
0215 00
REMOVAL - CONTINUED
1.
For hydraulic lines with split or regular flange fittings, remove four capscrews (1), washers (2), two split flanges or reg-
ular flange (3), line (4) and O-ring (5). Discard O-ring.
2.
For hydraulic lines with connector fittings, loosen connector (6) and remove line (7) from connection. Remove O-ring
(8) from connector and discard.
7
6
8
5
3
1,2
4
387-486
INSTALLATION
CAUTION
Wipe all sealing surfaces and line connections clean and dry before installation. Contamination of
hydraulic system could result in premature failure.
Utilize line wrenches for installation to avoid damage to fittings and connectors.
NOTE
Lightly coat new O-rings with clean oil before installation.
1.
For hydraulic lines with flange fittings, install end of line (4) with new O-ring, (5), two split flanges or regular flange
(3), four capscrews (1) and washers (2).
2.
For hydraulic lines with connector fittings, install new O-ring (8) on connector (6) and install end of line (7).
3.
Check oil level in hydraulic tank. Refill hydraulic tank and bleed air from system, as required (WP 0225 00).
4.
Check hydraulic system for proper operation and leaks (TM 5-2410-237-10).
5.
Ensure that oil level is still visible in sight gage on hydraulic tank. Add oil as needed (WP 0225 00).
END OF WORK PACKAGE