TM 5-2410-237-23
RIPPER CONTROL VALVE REPLACEMENT - CONTINUED
0206 00
INSTALLATION - CONTINUED
NOTE
Ripper control valve weighs 55 lb (25 kg).
Lightly coat new O-rings with clean oil before installation.
1.
Use a nylon sling and a suitable lifting device to position ripper control valve (6) to mounting bracket (49). Install valve
to mounting bracket with four washers (48) and capscrews (47).
2.
Install adapter (45) to bottom of ripper control valve (6).
3.
Install new O-ring (46) to pilot oil line (44) and connect pilot oil line to adapter (45).
4.
Install clamp (43) to pilot oil line (44) with washer
(42) and capscrew (41).
41,42,43
5.
Install guard (40) to tractor with four washers (39) and
capscrews (38).
44
40
38,39
387-619
6.
Install new O-ring (37) to line (36). Connect line to
36,37
33,34,35
ripper control valve (6) with two split flanges (35),
four washers (34) and capscrews (33).
387-618
0206 00-5
|