TM 5-2410-237-23
BLADE TILT AND RIPPER PILOT VALVE ASSEMBLY REPAIR - CONTINUED
0205 00
ASSEMBLY
NOTE
Lightly coat new O-rings with clean oil before assembly.
1.
Install three new O-rings (12) at large valve ports, new O-ring (13) at smaller port and two new small O-rings (14) at
smallest ports in inlet manifold (11).
2.
Repeat step 1 for ripper pilot valve (9).
3.
Repeat step 1 for blade tilt pilot valve (10).
CAUTION
Ensure all O-rings are properly seated when assembling manifolds and pilot valves, to avoid pinching or
cutting O-rings, which could cause leaks and system malfunctions.
4.
Position and carefully align inlet manifold (11), blade tilt pilot valve (10), ripper pilot valve (9) and outlet manifold (8)
together.
5.
Install three capscrews (7) to secure manifolds (8 and 11) and pilot valves (9 and 10).
6.
Apply six antiseize compound to pipe threads of adapters (6) and install adapters in pilot valve assembly (2).
7.
Apply antiseize compound to pipe threads of three elbows (5) and install elbows in pilot valve assembly (2).
8.
Install new shaft O-ring (4) and housing O-ring (3) in housing (1). Position housing over stem of ripper pilot valve (9).
9.
Install two washers and capscrews (removed when linkage was disconnected from pilot valve) finger tight to hold hous-
ing (1) on ripper pilot valve (9).
10.
Repeat steps 8 and 9 for blade tilt pilot valve (10).
11.
Install blade and ripper pilot valve assembly (WP 0205 00).
END OF WORK PACKAGE
0205 00-3
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |