TM 5-2410-237-23
NATO STARTING RECEPTACLE REPLACEMENT - CONTINUED
0102 00
REMOVAL - CONTINUED
2.
Remove four capscrews (7), washers (8) and self-locking nuts (9). Discard self-locking nuts.
3.
Remove cap (10), receptacle connector (6) and insulators (11 and 12) from bracket (13).
4.
If damaged, remove two capscrews (14), washers (15), nuts (16) and bracket (13) from guard.
5.
If damaged, remove four screws (17) and plate (18).
INSTALLATION
1.
If removed, install bracket (13) to guard with two capscrews (14), washers (15) and nuts (16).
2.
Install receptacle connector (6), insulators (11 and 12) and cap (10) to bracket (13) with four capscrews (7), washers (8)
and new self-locking nuts (9).
3.
Connect cables (4 and 5) to receptacle connector (6) and install two capscrews (1), starwashers (2) and lockwashers (3).
4.
If removed, install plate (18) with four screws (17).
5
7
4
3
2
10
1
6
11
12
8
13
9
16
14
15
18
387-331
17
5.
Connect battery cables (WP 0101 00).
END OF WORK PACKAGE
0102 00-2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |