TM 5-2410-237-23
BATTERY MAINTENANCE - CONTINUED
0100 00
INSTALLATION
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during pro-
cedure. Ensure that any lifting device used is in good condition and of suitable load capacity. Keep clear of
heavy parts supported only by lifting device. Failure to follow this warning may result in death or injury to
personnel.
NOTE
Each battery weighs 88 lb (39 kg).
1.
Attach a nylon sling and a suitable lifting device to handles of battery (2). Use lifting device to lower battery into battery
box.
2.
Repeat step 1 for battery (4).
3.
Place battery hold-down bracket (8) over studs of battery box. Install six washers (7) and new self-locking nuts (6).
4.
Connect cable (5) between batteries (2 and 4). Position boots over terminals.
5.
Connect positive battery cable (3) to positive terminal of battery (4). Position boot over terminal.
6.
Connect negative battery cable (1) to negative terminal on battery (2). Position boot over terminal.
7.
Install battery box cover (TM 5-2410-237-10).
END OF WORK PACKAGE
0100 00-3
|