Page Title: GENERAL LUBRICATION PROCEDURES
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home
   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-2410-237-23
UNIT MAINTENANCE PREVENTIVE MAINTENANCE CHECKS
AND SERVICES (PMCS) INTRODUCTION - CONTINUED
0009 00
GENERAL LUBRICATION PROCEDURES
NOTE
Lubrication instructions contained in this PMCS are MANDATORY.
Dashed leader lines used in illustrations of lubrication points indicate that lubrication is required on
both sides of the equipment.
1.
Recommended intervals are based on normal conditions of operation, temperature, and humidity. When operating under
extreme conditions, such as high or low temperatures or exposure to sand or dust, lubricants should always be changed
more frequently. Lubricants that have become contaminated will be changed regardless of interval. When in doubt,
notify your supervisor.
WARNING
When servicing this machine, performing maintenance or disposing of materials such as engine coolant,
hydraulic fluid, lubricants, battery acids or batteries, and CARC paint, consult your unit/local hazardous
waste disposal center or safety office for local regulatory guidance. If further information is needed, please
contact The Army Environmental Hotline at 1-800-872-3845.
2.
Ensure that all fluids drained as a result of lubrication or maintenance are collected in a suitable container and disposed
of in accordance with local policy and ordinances. Clean up any spills immediately.
3.
Keep all lubricants in a closed container and store in a clean, dry place away from extreme heat. Keep container covers
clean and do not allow dust, dirt or other foreign material to mix with lubricants. Keep all lubrication equipment clean
and ready for use.
4.
Maintain a good record of all lubrication performed and report any problem noted during lubrication. Refer to DA Pam
738-750 for maintenance forms and procedures to record and report any findings.
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic mate-
rial. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in well-venti-
lated areas. Keep away from open flames and other sources of ignition.
5.
Keep all external parts of equipment not requiring lubrication free of lubricants. Before lubrication, wipe lubrication fit-
tings with a clean rag (Item 29, WP 0249 00) and solvent cleaning compound (Item 2, WP 0249 00). After lubrication,
wipe off excess oil or grease to prevent accumulation of foreign matter.
6.
Refer to FM 9-207, Operations and Maintenance of Ordnance Materiel in Cold Weather, for lubrication instructions in
cold weather.
7.
Refer to AR 70-12, Fuel and Lubricant Standardization Policy for Equipment for use of standardized fuels and
lubricants.
8.
For equipment under manufacturer's warranty, hardtime oil service intervals shall be followed. Intervals shall be short-
ened if lubricants are known to be contaminated or if operation is under adverse conditions (i.e., longer-than-usual oper-
ating hours, extended idling periods or extreme dust).