TM 5-2410-237-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. If voltage is not indicated in
20. Defrosters Will Not Operate or Will Not
h. Place defroster control
either step g or h, replace
Operate in High Speed or Low Speed -
switch to high speed
defroster control switch (WP
Continued.
position and touch meter
positive lead to switch
high speed terminal.
Observe meter reading.
2. If voltage is not indicated in
both steps g and h, go to Table
6, Malfunction 20, Test 2.
3. If voltage is indicated in steps
both g and h, replace
defective defroster fan motor
387-908
DEFROSTER
CONTROL
SWITCH
BLACK LEAD
15A FUSE
387-908
2.
Test defroster switch for
a. Place battery disconnect
switch in OFF position.
d. Completely disconnect
defroster switch harness.
0006 00-80
Change 1
|