TM 5-2410-237-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5.
Starting Motor Inoperative - Continued.
e. Momentarily turn start
1. If voltage is indicated, go to
switch fully clockwise
Table 6, Malfunction 5, Test
and observe meter.
8.
2. If voltage is not indicated,
place battery disconnect
switch in OFF position,
reconnect white wire and go
to Table 6, Malfunction 5,
Test 11.
387-877
8.
Test for voltage between
starter relay and chassis
ground.
a. Place battery disconnect
switch in OFF position.
b. Disconnect ground from
starter relay.
c. Connect meter positive
lead to ground terminal on
relay (relay side).
d. Connect meter negative
lead to chassis ground.
0006 00-38
Change 1
|