CAUTION
(18) C o m p r e s s the retaining ring and remove
Do not exceed 300F or damage to the
the ring gear.
(19) R e m o v e the retaining ring.
turbine may result.
(22) Immediately after heating the rotating
(20
Remove turbine retaining ring (fig. 6-
housing and turbine assembly, turn 180 and install
15).
in. - 16 NC forcing screws in the flange
two
(21) Heat the rotating housing and turbine
a s s e m b l y ; s e p a r a t e the turbine. s p a c e r , and flange
assembly (fig. 6-15) in oil at a temperature of
assembly from rotating housing.
280 F-3000F for ten minutes.
6-16
|