RIPPER ASSEMBLY MAINTENANCE - CONTINUED
0173 00
INSTALLATION - CONTINUED
18.
Position connecting link (5).
19.
Install two pin assemblies (7) through connecting link (5).
20.
If removed, install grease fitting (8) to each side of each pin assembly (7).
21.
Install plate (4) at each end of connecting link (5) with two bolts (3).
22.
Repeat steps 16 through 21 for connecting link (5) on other side of ripper.
23.
Fill hydraulic tank and bleed system as needed (WP 0165 00).
24.
Install ripper shanks (WP 0175 00).
25.
Apply GAA grease to 20 ripper assembly grease fittings (TM 5-2410-233-10).
26.
Check ripper for proper operation (TM 5-2410-233-10).
5
7
8
4
3
7
8
4
386-579
3
END OF WORK PACKAGE