TM 5-2410-233-23
CHANGING HYDRAULIC SYSTEM OIL - CONTINUED
0165 00
FILLING
1.
Remove, clean and reinstall filler strainer (WP 0162 00).
2.
If required, change hydraulic filter element (WP 0162 00).
NOTE
To ensure an accurate reading on dipstick, oil in tank must be cool (at ambient temperature).
Refer to KEY in PMCS Introduction (WP 0008 00) for correct grade of oil for expected tem-
perature range of operation.
3.
Add oil to hydraulic tank (2) until oil is visible on dipstick (5).
BLEEDING SYSTEM
1.
Start engine and run at idle.
7
2.
Loosen plug (6) from pressure tap on manifold (7) to
right of seat.
3.
Let air escape and tighten plug (6) as soon as oil starts
to run out.
6
386-668
4.
Allow hydraulic system to cool, then check and fill hydraulic tank (2), as required.
5.
Install cap (1) on hydraulic tank (2).
6.
Operate machine and check for leaks and proper operation (TM 5-2410-233-10).
END OF WORK PACKAGE
0165 00-3
|