TM 5-2410-233-23
HYDRAULIC OIL FILTER ELEMENT AND FILLER STRAINER REPLACEMENT - CONTINUED
0162 00
FILTER ELEMENT CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic mate-
rial. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in well-venti-
lated areas. Keep away from open flames and other sources of ignition.
1.
Use solvent cleaning compound to clean components.
2.
Replace any damaged component.
FILTER ELEMENT INSTALLATION
1.
Install new filter element (13) in hydraulic tank (14) with retaining nut (12).
2.
Install springs (11), seat valve (10), seat assembly (9) and new cotter pin (8).
3.
Install spring (6 and 7) and position new gasket (5) on cover (4). Install cover.
NOTE
Lightly coat new O-ring with clean oil before installation.
4.
Install new O-ring (3), washer (2) and capscrew (1).
5.
Check oil level in hydraulic tank (14). Add oil if necessary (WP 0165 00).
6.
Retighten filler cap (15) on hydraulic tank (14).
0162 00-3
|