BLADE LIFT CYLINDER REPLACEMENT - CONTINUED
0157 00
INSTALLATION - CONTINUED
CAUTION
Wipe all sealing surfaces and hose connections clean and dry before installation. Contamination of hydrau-
lic system could result in premature failure.
NOTE
Lightly coat new O-rings with clean oil before installation.
7.
Install new O-ring (5) and tube (4) to lift cylinder (6)
8
5 (HIDDEN)
6
1,2,3
with two split flanges (3), four new lockwashers (2)
and bolts (1).
8.
Repeat step 7 to install other end of tube (4) to
4
manifold (7).
9.
Repeat steps 7 and 8 to install tube (8).
7
386-805
386-805
0157 00-6