FINAL DRIVE SERVICE - CONTINUED
0099 00
SERVICE - CONTINUED
6.
Install new gasket (2) and fill plug (1) in final drive
housing (3).
NOTE
Each final drive and transmission share a com-
3
mon breather. Repeat step 7 for breather on
each side.
7.
Remove breather (5) from steering clutch and final
drive case cover.
1, 2
386-107
LEFT SIDE
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low
toxic material. However, it may be irritating to the eyes and skin. Use protective gloves and
goggles. Use in well-ventilated areas. Keep away from open flames and other sources of igni-
tion.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle
pressure when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when
cleaning components. DO NOT direct compressed air against human skin. Failure to follow
this warning may result in serious injury or death. Make sure air stream is directed away
from user and other personnel in the area. To prevent injury, user must wear protective gog-
gles or face shield.
8.
Clean breather (5) with solvent cleaning compound and dry with compressed air.
0099 00-2
|