|
|
TM 5-2410-233-23
BATTERY CABLES REPLACEMENT - CONTINUED
0080 00
REMOVAL
WARNING
Turn battery disconnect switch to OFF position before working on battery cables. Failure to
follow this warning could result in injury or damage to equipment.
To avoid injury, eye protection and acid-resistant gloves must be worn when working around
batteries. Do not smoke, use open flame, make sparks or create other ignition sources around
batteries. If a battery is giving off gases, it can explode and cause injury to personnel. Remove
all jewelry such as rings, ID tags, watches, and bracelets. If jewelry or a tool contacts a battery
terminal, a direct short will result in instant heating, damage to equipment and injury to per-
sonnel.
Sulfuric acid contained in batteries can cause serious burns. If battery corrosion or electrolyte
makes contact with skin, eyes or clothing, take immediate action to stop the corrosive burning
effects. Failure to follow these procedures may result in injury or death.
1.
Remove floor plates for access to remove cables (WP 0135 00).
NOTE
Tag cables to ensure correct installation.
Lift up rubber boots for access to cable terminals.
2.
Loosen nut and disconnect negative battery cable (1)
5
from negative post of battery (2).
3.
Loosen nut and disconnect positive battery cable (3)
from positive post of battery (4).
4.
Loosen two nuts and disconnect battery cable (5) from
between posts of batteries (2 and 4).
386-645
3
2
1
4
0080 00-2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |