TM 5-2410-233-23
AMMETER REPLACEMENT - CONTINUED
0073 00
REMOVAL - CONTINUED
NOTE
Tag wires to ensure correct installation.
2.
Remove two nuts (6), washers (7), two wires (8), two lockwashers (9) and bracket (10) from back of ammeter (11).
Discard lockwashers.
3.
Slide ammeter (11) with seal (12) out through front of dash assembly (5).
4.
Remove seal (12) from ammeter (11). Discard seal.
7
9
10
5
6
8
386-440
12
11
INSTALLATION
1.
Install new seal (12) on ammeter (11).
2.
Insert ammeter (11) into position on dash assembly (5).
3.
Install two new lockwashers (9), wires (8), washers (7) and nuts (6) on bracket (10) to back of ammeter (11).
4.
Install cover (4) on top of dash assembly (5) with four
5
4
1,2,3
capscrews (1), washers (2) and new lockwashers (3).
5.
Connect battery cables (WP 0080 00).
6.
Turn battery disconnect switch to ON position (TM 5-
2410-233-10).
7.
Start engine and check for proper operation of
ammeter (TM 5-2410-233-10).
386-651
END OF WORK PACKAGE
0073 00-2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |