RADIATOR MAINTENANCE - CONTINUED
0063 00
REMOVAL - CONTINUED
18.
Remove capscrew (46) and lockwasher (47) from front mounting bracket (48). Discard lockwasher.
19.
Remove nut (49), lockwasher (50) and capscrew (51) from front angle bracket (52). Discard lockwasher.
20.
Remove three inner top radiator mounting nuts (53), lockwashers (54), capscrews (55) and washers (56). Separate front
angle bracket (52) and double-angle front mounting bracket (57). Discard lockwashers.
21.
Remove bushing (58) from front mounting bracket (48), if required.
22.
Repeat step 18 through 21 for other side of radiator (10).
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during
procedure. Ensure that any lifting device used is in good condition and of suitable load capacity. Keep clear
of heavy parts supported only by lifting device. Failure to follow this warning may cause injury or death to
personnel.
CAUTION
Ensure that wiring harness from flood lights, located between radiator and support, is clear of radiator. Lift
radiator slowly and carefully to avoid damage to wiring harness.
NOTE
Radiator weighs 450 lb (204 kg)
23.
With suitable lifting device attached to lifting links (33), lift radiator (10) clear of machine.
24.
Remove nylon sling and lifting device.